2 Parameters
2.4 Parameters for write protection and know-how protection
SINAMICS G130/G150
1088
List Manual (LH2), 07/2016, A5E03263479A
2.4.2
Parameters with "KHP_WRITE_NO_LOCK"
The following list contains the parameters with the "KHP_WRITE_NO_LOCK" attribute.
These parameters are not affected by the know-how protection.
Product: SINAMICS G130/G150, Version: 4806000, Language: eng, Type: KHP_WRITE_NO_LOCK
p0003
BOP access level / BOP acc_level
p0009
Device commissioning parameter filter / Dev comm par_filt
p0124[0...n]
Main component detection using LED / M_comp detect LED
p0124[0...n]
Power unit detection via LED / PU detection LED
p0144[0...n]
Sensor Module detection via LED / SM detection LED
p0154
Terminal Module detection via LED / TM detection LED
p0154
DRIVE-CLiQ Hub Module detection via LED / Hub detection LED
p0972
Drive unit reset / Drv_unit reset
p0976
Reset and load all parameters / Reset load all par
p0977
Save all parameters / Save all par
p2035
Fieldbus interface USS PIV drive object number / Fieldbus USS DO_no
p2040
Fieldbus interface monitoring time / Fieldbus t_monit
p2102
BI: Acknowledge all faults / Ackn all faults
p2111
Alarm counter / Alarm counter
p3100
RTC time stamp mode / RTC t_stamp mode
p3101[0...1]
Setting UTC time / Set UTC time
p3103
UTC synchronization process / UTC sync_process
p3950
Service parameter / Serv par
p3981
Acknowledge drive object faults / Ackn DO faults
p3985
Master control mode selection / PcCtrl mode select
p7761
Write protection / Write protection
p7770
NVRAM action / NVRAM action
p8550
AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
p8806[0...53]
Identification and Maintenance 1 / I&M 1
p8807[0...15]
Identification and Maintenance 2 / I&M 2
p8808[0...53]
Identification and Maintenance 3 / I&M 3
p8809[0...53]
Identification and Maintenance 4 / I&M 4
p8829
CBE2x remote controller number / CBE2x rem ctrl num
p8835
CBE20 firmware selection / CBE20 FW sel
p8839[0...1]
PZD interface hardware assignment / PZD IF HW assign
p8840
COMM BOARD monitoring time / CB t_monit
p9210
Flashing component number / Flash comp_no.
p9211
Flash function / Flash fct.
p9484
BICO interconnections search signal source / BICO S_src srch
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......