2 Parameters
2.2 List of parameters
SINAMICS G130/G150
636
List Manual (LH2), 07/2016, A5E03263479A
Description:
Successfully completed component of the last rotating measurement carried out.
Dependency:
Refer to: r3925
Note:
The parameter is a copy of p1959.
Description:
Selecting the calculation of the motor/controller data for the offline parameterization Startdrive
Value:
0:
No calculation
1:
Complete calculation
3:
Calculation without equivalent circuit diagram data
Dependency:
The parameter is preassigned when changing the motor.
Refer to: p0340
Description:
For service personnel only.
r3928[0...n]
Rotating measurement configuration / Rot meas config
VECTOR_G (n/M)
Can be changed:
-
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Unsigned16
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor identification
Unit group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enc test active
Yes
No
-
01
Saturation characteristic identification
Yes
No
-
02
Moment of inertia identification
Yes
No
-
03
Re-calculates the speed controller
parameters
Yes
No
-
04
Speed controller optimization (vibration test) Yes
No
-
05
q leakage inductance ident. (for current
controller adaptation)
Yes
No
-
11
Do not change the controller parameters
during the measurement
Yes
No
-
12
Measurement shortened
Yes
No
-
13
After measurement direct transition into
operation
Yes
No
-
14
Calculate speed actual value smoothing
time
Yes
No
-
p3940[0...n]
Motor/controller data calculation / Mot/ctrl_data calc
VECTOR_G
Can be changed:
C2, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
All groups
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 3
0
p3950
Service parameter / Serv par
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
C1, U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
All groups
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......