SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
425
2 Parameters
2.2 List of parameters
Description:
Displays the currently applied pulse patterns for estimating the continuous rotor position.
Value:
0:
None
1:
pm
2:
ppmm
Dependency:
Refer to: p1605, p1750
Description:
Sets the excitation amplitude (voltage-time pulse) for the pulse technique for estimating the continuous rotor position.
Dependency:
Refer to: p1605, p1750
Description:
Displays the signal responses to the excitation of the pulse technique.
Index:
[0] = Phase R
[1] = Phase S
[2] = D estimated
[3] = Q estimated
[4] = D estimated AC
[5] = Q estimated AC
[6] = Pointer length AC
[7] = D estimated AC smooth
[8] = Q estimated AC smooth
Dependency:
Refer to: p1605, p1607, p1750
Note:
For index 7, 8:
Displays the smoothed values (smoothing time p0045) from indices 4 and 5.
Description:
Sets the stator current setpoint for operation of a separately excited synchronous motor (SESM) in operating mode I/f
(p1300 = 18).
r1606
CO: Pulse technique pattern actual / Puls pattern act
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
-
p1607[0...n]
Pulse technique stimulus / Puls stimulus
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Unit group:
-
Unit selection:
-
Not for motor type:
ASM, SESM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [mVs]
20000.000 [mVs]
32.000 [mVs]
r1608[0...8]
CO: Pulse technique response / Puls response
VECTOR_G (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Displays, signals
Unit group:
6_5
Unit selection:
p0505
Not for motor type:
ASM, SESM, REL
Scaling:
p2002
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
p1609[0...n]
I/f operation current setpoint / I/f op I_setp
VECTOR_G (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6727
P-Group:
Closed-loop control
Unit group:
6_2
Unit selection:
p0505
Not for motor type:
ASM, PMSM, REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
10000.00 [Arms]
0.00 [Arms]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......