2 Parameters
2.2 List of parameters
SINAMICS G130/G150
216
List Manual (LH2), 07/2016, A5E03263479A
For p0496 = 12: 180 ° fine position <--> 32768 dec
For p0496 = 13 (resolver): 2900 mV <--> 13107 dec
For p0496 = 13 (sin/cos 1 Vpp, EnDat): 500 mV <--> 10650 dec
For p0496 = 14: 1 ° <--> 286 dec, 100 % <--> 16384 dec
For p0496 = 15: 100 % <--> 16384 dec
For p0496 = 16: (resolver): channel A: 2900 mV <--> 26214 dec, channel B: 2900 mV <--> 26214 dec
For p0496 = 16: (sin/cos 1 Vpp, EnDat) channel A: 500 mV <--> 21299 dec, channel B: 500 mV <--> 21299 dec
For p0496 = 17 (resolver): absolute value: 2900 mV <--> 13107 dec, number: 1 ... 8
For p0496 = 17 (sin/cos 1 Vpp, EnDat): absolute value 500 mV <--> 10650 dec, number: 1 ... 8
For p0496 = 18 (resolver): angle: signal period <--> 2^16, absolute value: 2900 mV <--> 13107 dec
For p0496 = 18 (sin/cos 1 Vpp, EnDat): angle: signal period <--> 2^16, absolute value: 500 mV <--> 10650 dec
For p0496 = 19 (resolver): counter: dec, channel A: 2900 mV <--> 26214 dec
For p0496 = 19 (sin/cos 1 Vpp, EnDat): counter: dec, channel A: 500 mV <--> 21299 dec
For p0496 = 22: 180 ° <--> 32768 dec
For p0496 = 23, 24: r0497.31 (r0499.15) set for at least 1 current controller sampling time when encoder zero mark
detected
For p0496 = 24, 25: 500 mV <--> 21299 dec
For p0496 = 30: Rotary: 1 singleturn measuring step <--> 1 dec, linear: 1 measuring step <--> 1 dec
For p0496 = 31: Absolute position, incremental in 1/4 encoder pulses
For p0496 = 32: Zero mark position in 1/4 encoder pulses
For p0496 = 33: counter offset absolute value in 1/4 encoder pulses
For p0496 = 40: r0498 <--> (R_KTY/1 kOhm - 0.9) * 32768
For p0496 = 42: 2500 Ohm <--> 2^32
For p0496 = 51: 1 rpm <--> 1000 dec
For p0496 = 52: In 1/4 encoder pulses
For p0496 = 60: voltage, channel A in mV, voltage, channel B in mV
For p0496 = 61: Channel A: encoder periods <--> 2^16, channel B: encoder periods <--> 2^16
For p0496 = 62: encoder periods <--> 2^16
For p0496 = 70: r: 100% <--> 10000 dec, phase: 180 ° <--> 18000 dec
For p0496 = 80, 81, 85, 86: 1V <--> 1000 inc
Description:
Selects the trace signal to be output in r0497, r0498 and r0499 for encoder diagnostics.
Value:
0:
Inactive
1:
r0497: Mechanical revolution
7:
r0498: oversampling channel A with fault trigger
8:
r0498: oversampling channel A with fault trigger
9:
r0497: sum of the squares AB in 0.1 mV
10:
r0498: Raw value track A, r0499: Raw value track B
11:
r0498: Fine position X (-A/2), r0499: Fine position Y (-B/2)
12:
r0498: Fine position Phi, r0499: -
13:
r0498: Offset correction X, r0499: Offset correction Y
14:
r0498: Phase correction X, r0499: Amplitude correction Y
15:
r0498: Cubic correction X, r0499: Fine position X
16:
r0498: oversampling channel A, r0499: oversampling channel B
17:
r0498: fan-out amount, r0499: fan-out number
18:
r0498: Oversampling angle, r0499: Oversampling amount
19:
r0498: Fault counter AB, r0499: raw value track A
20:
r0498: Raw value track C, r0499: Raw value track D
21:
r0498: CD position X (-D/2), r0499: CD position Y (C/2)
22:
r0498: CD position Phi, r0499: CD pos. Phi - mech. revolution
23:
r0497: Zero mark status
p0496
Encoder diagnostic signal selection / Enc diag select
ENC
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 86
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......