SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
569
2 Parameters
2.2 List of parameters
Description:
Sets the maximum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2238
Description:
Sets the minimum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2237
Description:
Sets the starting value for the motorized potentiometer of the technology controller.
For p2230.0 = 0, this setpoint is entered after ON.
Dependency:
Refer to: p2230
Description:
Sets the effective setpoint in front of the internal motorized potentiometer ramp-function generator of the technology
controller.
Dependency:
Refer to: r2250
p2237[0...n]
Technology controller motorized potentiometer maximum value / Tec_ctrl mop max
VECTOR_G
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
7954
P-Group:
Technology
Unit group:
9_1
Unit selection:
p0595
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
100.00 [%]
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
VECTOR_G
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
7954
P-Group:
Technology
Unit group:
9_1
Unit selection:
p0595
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
-100.00 [%]
p2240[0...n]
Technology controller motorized potentiometer starting value / Tec_ctrl mop start
VECTOR_G
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
7954
P-Group:
Technology
Unit group:
9_1
Unit selection:
p0595
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
0.00 [%]
r2245
CO: Technology controller mot. potentiometer setpoint before RFG /
Tec_ctr mop befRFG
VECTOR_G
(Tech_ctrl)
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
7954
P-Group:
Technology
Unit group:
9_1
Unit selection:
p0595
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......