2 Parameters
2.2 List of parameters
Description:
Displays the required memory in bytes for the actual parameterization.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
Description:
Displays the required memory in bytes for the actual parameterization.
This applies, if the trace for the measurement functions is used.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
Description:
Sets the trigger condition for the trace.
Value:
1:
Immediate trace start
2:
Positive edge
3:
Negative edge
4:
Entry to hysteresis band
5:
Leaving hysteresis band
6:
Trigger at bit mask
7:
Start with function generator
8:
Trigger at bit mask with edge
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Selects the trigger signal for the trace.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
r4708[0...1]
Trace memory space required / Trace mem required
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4709[0...1]
Trace memory space required for measuring functions / Trace mem required
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
p4710[0...1]
Trace trigger condition / Trace Trig_cond
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
1 8
2
p4711[0...5]
Trace trigger signal / Trace trig_signal
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
0
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......