SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
925
2 Parameters
2.2 List of parameters
Description:
Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9492, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9491, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Setting to reset the BICO interconnections to other drives.
Each interconnection can be individually reset.
Value:
0:
Set connection to 0
1:
Set connection to 1 (100 %)
2:
Set connection to factory setting
15:
Finished
Dependency:
Refer to: r9490, r9491, r9492
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
r9491[0...9]
BI/CI of BICO interconnections to other drives / BI/CI to drive
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9492[0...9]
BO/CO of BICO interconnections to other drives / BO/CO to drive
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Commands
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p9493[0...9]
Reset BICO interconnections to other drives / Reset BICO to drv
All objects
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 15
15
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......