2 Parameters
2.2 List of parameters
SINAMICS G130/G150
72
List Manual (LH2), 07/2016, A5E03263479A
Note:
The transformation angle corresponds to the electrical commutation angle.
If no pole position identification is carried out (p1982), and the encoder is adjusted, the following applies:
The encoder supplies the value and indicates the electrical angle of the flux position (d axis).
Description:
Executes an automatic device configuration.
In so doing, p0099, p0107 and p0108 are appropriately set.
Value:
0:
No selection
1:
Drive object type SERVO
2:
Drive object type VECTOR
3:
SINAMICS GM (DFEMV & VECTORMV)
4:
SINAMICS SM (AFEMV & VECTORMV)
5:
SINAMICS GL (VECTORGL)
6:
SINAMICS SL (VECTORSL)
12:
Drive object type VECTOR parallel circuit
13:
Drive object type VECTORMV - GM parallel circuit
14:
Drive object type VECTORMV - SM parallel circuit
15:
Drive object type DC_CTRL
16:
Drive object type SERVO HMI
17:
Drive object type VECTOR HMI
24:
Drive object type VECTORMV - SM parallel circuit
Dependency:
Refer to: r0098, p0099
Refer to: A01330
Note:
For p0097 = 0, p0099 is automatically set to the factory setting.
The possible settings are dependent upon the device type.
Description:
Displays the automatically detected actual device topology in coded form.
Index:
[0] = DRIVE-CLiQ socket X100
[1] = DRIVE-CLiQ socket X101
[2] = DRIVE-CLiQ socket X102
[3] = DRIVE-CLiQ socket X103
[4] = DRIVE-CLiQ socket X104
[5] = DRIVE-CLiQ socket X105
Dependency:
Refer to: p0097, p0099
Note:
Topology coding: abcd efgh hex
a = number of Active Line Modules
b = number of Motor Modules
c = number of motors
d = number of encoders (or the line supply voltage sensing for Active Line Modules)
e = number of additional encoders (or the line supply voltage sensing for Active Line Modules)
f = number of Terminal Modules
g = number of Terminal Boards
h = reserved
p0097
Select drive object type / Select DO type
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
C1(1)
Calculated:
-
Access level:
1
Data type:
Integer16
Dyn. index:
-
Func. diagram:
-
P-Group:
Topology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 24
0
r0098[0...5]
Actual device topology / Device_act topo
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Topology
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......