2 Parameters
2.2 List of parameters
SINAMICS G130/G150
106
List Manual (LH2), 07/2016, A5E03263479A
Dependency:
Refer to: r0193
Notice:
This information represents the characteristics/features of the power unit firmware. It does not provide
information/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware
supports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note:
For bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage
protection (p1231 = 3).
For bit 10:
The Motor Module supports the autonomous internal voltage protection.
If the "internal voltage protection" function is activated (p1231 = 3) the Motor Module decides autonomously - using
the DC link voltage - as to whether the short-circuit is activated.
For bit 23:
The component supports the detection of current actual values (and the detection of valve close durations) with
double clocking and phase shift.
06
Liquid cooling
Yes
No
-
07
SERVO pulse frequency changeover DDS-
dependent
Yes
No
-
08
Simulation mode possible
Yes
No
-
09
Internal armature short-circuit possible
Yes
No
-
10
Autonomous internal armature short-circuit
possible
Yes
No
-
11
Infeed temperature inputs X21.1/2
Yes
No
-
12
Integral scaled to half the gating unit clock
cycle freq.
Yes
No
-
13
Filtering thermal power unit current limit
possible
Yes
No
-
14
DC link compensation possible in power unit Yes
No
-
15
PT100 temperature evaluation possible
Yes
No
-
16
Gating unit with pulse frequency
wobbulation possible
Yes
No
-
17
Compound braking possible
Yes
No
-
18
Extended voltage range possible
Yes
No
-
19
Gating unit available with current limitation
control
Yes
No
-
20
Component status possible
Yes
No
-
21
Temperature evaluation via Motor Module /
CU terminals possible
Yes
No
-
22
Reduced device supply voltage possible
Yes
No
-
23
Current measurement oversampling
available
Yes
No
-
24
Parking keeping the relevant data is
available
Yes
No
-
25
Internal fan operating hours counter
available
Yes
No
-
26
Software gating unit supported in the
Control Unit
Yes
No
-
27
Current controller dynamics higher
Yes
No
-
28
Reserved
-
29
Voltage measurement
Yes
No
-
30
Gating unit with all-phase current limiting
Yes
No
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......