2 Parameters
2.2 List of parameters
SCC: Safety Control Channel
SDI: Safe Direction (safe motion direction)
SI: Safety Integrated
SLP: Safely Limited Position
SP: Safe Position
SS1: Safe Stop 1
SS1E: Safe Stop 1 External (Safe Stop 1 with external stop)
SS2E: Safe Stop 2 external (Safe Stop 2 with external stop, external STOP D)
SSM: Safe Speed Monitor (safety-related feedback signal from the velocity monitoring) / SGA n < nx: Safety-related
output n < nx
STO: Safe Torque Off / SH: Safe standstill
For bit 16:
SS1E is supported for Safety Extended Functions.
Description:
Display and BICO output for the Safety Integrated status on the Control Unit.
Dependency:
Refer to: r9872
Note:
For bit 00:
When STO or "Safe pulse cancellation" is selected, the cause is displayed in bits 16 ... 21.
For bit 01:
- For p9772.1 = 1 and p9772.19 = 0, an STO from the Safety Basic functions is active.
- For p9772.1 = 1 and p9772.19 = 1, safe pulse cancellation is active, if safety functions without selection are
activated via p9601.2/p9801.2 = 1 and p9601.5/p9801.5 = 1.
Note:
If p9601.0 = 1 and p9601.2 = 1 and p9801.5 = 1 then for bit 0 and 1, the STO function applies.
r9772.0...23
CO/BO: SI status (Control Unit) / SI status CU
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2804
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO or safe pulse cancellation on CU
selected
Yes
No
2810
01
STO or safe pulse cancellation on CU active Yes
No
2810
02
SS1 delay time active on CU
Yes
No
2810
04
SBC requested
Yes
No
2814
05
SS1 on CU selected (Basic Functions)
Yes
No
-
06
SS1 on CU active (Basic Functions)
Yes
No
-
07
STO terminal state on CU (Basic Functions) High
Low
-
09
STOP A cannot be acknowledged active
Yes
No
2802
10
STOP A active
Yes
No
2802
15
STOP F active
Yes
No
2802
16
STO cause: Safety comm. mode
Yes
No
-
17
STO cause selection via terminal (Basic
Functions)
Yes
No
-
18
STO cause selection via Safe Motion
Monitoring (SMM)
Yes
No
-
19
STO cause actual value missing or safe
pulse cancellation
Yes
No
-
20
STO cause selection PROFIsafe/TM54F
(Basic Functions)
Yes
No
-
21
STO cause selection on other monitoring
channel
Yes
No
-
22
SS1 cause selection terminal (Basic
Functions)
Yes
No
-
23
SS1 cause selection PROFIsafe/TM54F
(Basic Functions)
Yes
No
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......