2 Parameters
2.2 List of parameters
SINAMICS G130/G150
98
List Manual (LH2), 07/2016, A5E03263479A
Description:
This parameter is used to assign the data set to a DRIVE-CLiQ Hub Module.
This unique component number is assigned when parameterizing the topology.
Only the numbers of components operated as hubs can be entered in these parameters.
[0] = DRIVE-CLiQ node 1
[1] = DRIVE-CLiQ node 2
Description:
Detects the Terminal Module assigned to this drive and data set.
Note:
While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Terminal Module.
Description:
Detects any DRIVE-CLiQ Hub Module that has been assigned.
Description:
Setting to activate/deactivate a Voltage Sensing Module (VSM).
Value:
0:
Deactivate component
1:
Activate component
2:
Component deactivate and not present
Recommendation:
After inserting a component, before activating, first wait for Alarm A01317.
Dependency:
Refer to: r0156
Refer to: A01314, A01317
p0151[0...1]
DRIVE-CLiQ Hub Module component number / Hub comp_no
HUB
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 199
0
p0154
Terminal Module detection via LED / TM detection LED
TM31, TM120, TM150,
TM54F_MA,
TM54F_SL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Terminals
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p0154
DRIVE-CLiQ Hub Module detection via LED / Hub detection LED
HUB
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p0155[0...n]
Voltage Sensing Module activate/deactivate / VSM act/deact
VECTOR_G
Can be changed:
C1(4), T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
p0150
Func. diagram:
-
P-Group:
Data sets
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 2
1
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......