2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1010
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on the Motor Module/Hydraulic Module.
Dependency:
Refer to: r0110, p0115, r9780
Note:
Information about the interrelationship between the monitoring clock cycle and the response times can be taken from
the technical documentation on the particular product.
Description:
Displays the Node Identifier of the Sensor Module that the second channel uses for the motion monitoring functions.
Description:
Displays the Safety Integrated version on the Sensor Module.
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency:
Refer to: r9770, r9870
Note:
Example:
r9890[0] = 2, r9890[1] = 3, r9890[2] = 1 --> Safety-Version V02.03.01
Description:
Displays the number of the data that are being presently compared crosswise on the Motor Module/Hydraulic
Module.
The content of the list of crosswise-compared data is dependent upon the particular application.
Dependency:
Refer to: r9794
Note:
CDC: Crosswise Data Comparison
Example:
r9894[0] = 1 (monitoring clock cycle)
r9894[1] = 2 (enable safety functions)
r9880
SI monitoring clock cycle (Motor Module) / SI monitor_clck MM
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9881[0...11]
SI Motion Sensor Module Node Identifier second channel / SI Mtn SM Ident
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9890[0...2]
SI version (Sensor Module) / SI version SM
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9894[0...19]
SI crosswise comparison list (Motor Module) / SI CDC_list MM
VECTOR_G
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dyn. index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......