2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1058
List Manual (LH2), 07/2016, A5E03263479A
Description:
Displays the communication status of the individual drives with the Terminal Module 54F (TM54F).
For r10055 = 0, the following applies:
All drives assigned in p10010 communicate with the TM54F.
Description:
Display and BICO output for the status of the Terminal Module 54F (TM54F).
Description:
Enters the Safety Integrated password for the Terminal Module 54F (TM54F).
This password is required to change the safety-relevant parameters.
r10055
SI TM54F communication status drive-specific / SI comm_stat drv
TM54F_MA,
TM54F_SL
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Communication between drive 1 and
TM54F
Not configured
Configured
-
01
Communication between drive 2 and
TM54F
Not configured
Configured
-
02
Communication between drive 3 and
TM54F
Not configured
Configured
-
03
Communication between drive 4 and
TM54F
Not configured
Configured
-
04
Communication between drive 5 and
TM54F
Not configured
Configured
-
05
Communication between drive 6 and
TM54F
Not configured
Configured
-
r10056.0
CO/BO: SI TM54F status / SI stat
TM54F_MA
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Test stop status
Active
Inactive
-
p10061
SI TM54F password input / SI password inp
TM54F_MA,
TM54F_SL
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
2891
P-Group:
Safety Integrated
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......