Parameters
List of parameters
1-980
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" is set.
Dependency:
Refer to: p9546
Caution:
The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" is set.
Dependency:
Refer to: p9546
Caution:
The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description:
Sets the velocity tolerance for the "Safe Acceleration Monitor".
Dependency:
Refer to: p9548
Refer to: C01706
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
p9346
SI motion SSM velocity limit (Motor Module) / SI Mtn SSM v_limMM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [mm/min]
1000000.00 [mm/min]
20.00 [mm/min]
p9346
SI motion SSM velocity limit (Motor Module) / SI Mtn SSM v_limMM
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
1000000.00 [RPM]
20.00 [RPM]
p9348
SI motion SBR actual velocity tolerance (Motor Module) / SI Mtn SBR Tol MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [mm/min]
120000.00 [mm/min]
300.00 [mm/min]