Basic Operator Panel 20 (BOP20) - Control word interconnection
STW BOP.0
STW BOP.1
STW BOP.2
STW BOP.3
STW BOP.4
STW BOP.5
STW BOP.6
STW BOP.8
STW BOP.9
STW BOP.11
STW BOP.12
STW BOP.13
STW BOP.14
STW BOP.15
STW BOP.7
STW BOP.10
p0848[0] = r0019.2
-
-
-
-
p2102[0] = r0019.7
-
-
-
-
-
p1035[0] = r0019.13
p1036[0] = r0019.14
-
p0840[0] = r0019.0
p0844[0] = r0019.1
1 = On
0 = OFF (OFF1)
1 = No coast down
0 = Coast down (OFF2)
1 = No fast stop
0 = Fast stop (OFF3)
= Acknowledge fault
Reserved
Reserved
Reserved
1 = Motorized potentiometer, raise
Reserved
1 = Motorized potentiometer, lower
Interconnection STW BOP (r0019)
Signal
Interconnection
parameters
Meaning
Refer to [1020.7]
PROFIdrive sampling time
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
<1>
<1> The BICO interconnection represents an example that can be be changed by the user.