List of parameters
Parameters
1-445
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output without taking
into account the current and power limits.
Description:
Sets the signal source for the scaling of the lower force limiting to limit the velocity controller output without taking
into account the current and power limits.
Description:
Sets the signal source for the motoring and negative regenerative power limit.
Dependency:
Refer to: p1530, p1531
Note:
The resulting power limit when motoring is the minimum from p1530 and the signal that is read-in, the resulting
regenerative power limit is the maximum from p1531 and the negative signal that is read-in.
Description:
Sets the scaling of the signal source for the motoring and negative regenerative power limit.
0 signifies no power limiting.
Description:
Sets the signal source for supplementary torque 3.
p1554[0...n]
CI: Torque limit lower scaling without offset / M_max low offsScal
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6060
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1
p1554[0...n]
CI: Force limit lower scaling without offset / F_max low offsScal
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6060
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1
p1555[0...n]
CI: Power limit / P_max
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6640
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1
p1556[0...n]
Power limit scaling / P_max_scale
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
6640
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 340.28235E36
0.00
p1569[0...n]
CI: Supplementary torque 3 / M_suppl 3
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
7010
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
3841[0]