Parameters
List of parameters
1-514
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the stator flux of the identified saturation characteristic.
The values are referred to the stator flux at the magnetizing current (r0331).
Dependency:
Refer to: p1959, p1960, r1962
Note:
The saturation characteristic consists of the value pairs from p1962 and p1963 with the same index.
Description:
Displays the magnetizing inductances of the identified saturation characteristic.
The values are referred to r0382.
Index:
[0] = Value 1
[1] = Value 2
[2] = Value 3
[3] = Value 4
[4] = Value 5
Dependency:
Refer to: r0382
Description:
Displays the rotor flux values of the identified saturation characteristic.
After they have been determined, the values are transferred to p0362 ... p0365.
Index:
[0] = Value 1
[1] = Value 2
[2] = Value 3
[3] = Value 4
[4] = Value 5
Description:
Sets the speed for the identification of the moment of inertia and the vibration test.
Induction motor:
r1963[0...9]
Saturation characteristic stator flux identified / Sat_char flux
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r1963[0...4]
Saturation characteristic, magnetizing inductance / Sat_char L_main
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r1964[0...4]
Saturation characteristic, rotor flux / Sat_char rot flux
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p1965
Speed_ctrl_opt speed / n_opt speed
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
10 [%]
75 [%]
40 [%]