Parameters
List of parameters
1-518
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the pole position identification technique.
Values:
0:
Saturation-based 1st+ 2nd harmonics
1:
Saturation-based 1st harmonics
4:
Saturation-based, 2-stage
10:
Motion-based
99:
No technique selected
Dependency:
Refer to: p0325, p0329, p1981, p1982, p1983, r1984, r1985, r1987
Notice:
If the incorrect technique is applied, this can cause the motor to accelerate in an uncontrolled fashion.
Note:
When commissioning a list motor, the technique is automatically selected depending on the motor type being used.
The following applies for 1FN3 motors:
A technique with 2nd harmonic may not be used (do not use p1980 = 0, 4).
For 1FN7 motors, the following applies:
A two-stage technique may not be used (do not use p1980 = 4).
The automatically set value in p0329 may not be changed.
Description:
Sets the pole position identification technique.
Values:
1:
Voltage pulsing, first harmonic
4:
Voltage pulsing, 2-stage
10:
DC current impression
Dependency:
In the simulation mode, the parameter cannot be written into.
Refer to: p1272
Note:
Voltage pulse technique (p1980 = 1, 4) cannot be applied to separately-excited synchronous motors (p0300 = 5)
and for for operation with sinusoidal output filters (p0230).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Speed controller optimization activated
Yes
No
-
01
Speed controller optimization completed
Yes
No
-
02
Speed controller optimization interrupted
Yes
No
-
04
Enc test active
Yes
No
-
05
Saturation char. identification active
Yes
No
-
06
Moment of inertia identification active
Yes
No
-
07
Recalc. speed controller parameters active
Yes
No
-
08
Speed controller vibration test active
Yes
No
-
09
Magnetizing induction adapt. active
Yes
No
-
10
Operation with encoder after sensorless
operation
Yes
No
-
11
q-leakage inductance identification
Yes
No
-
p1980[0...n]
Pole position identification technique / PolID technique
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Integer16
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 99
99
p1980[0...n]
Pole position identification technique / PolID technique
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
ASM
Expert list:
1
Min Max
Factory
setting
1 10
4