List of parameters
Parameters
1-517
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the number of periods determined by the vibration test.
Index:
[0] = No. of periods of the low frequency
[1] = No. of periods of the high frequency
Dependency:
Refer to: p1959
Refer to: F07985
Description:
Index 0:
For rotating motors, displays the identified encoder pulse number (per revolution). For linear motors: Encoder pulse
number per meter. Grid division = 1/p1973 [meter].
Index 1:
For linear motors: identified grid division in nm.
No significance for rotating motors.
Index:
[0] = Rotating motor encoder pulse number
[1] = Linear motor, grid division in nm
Notice:
Due to the measuring accuracy (approx. 5%) only the approximate value is shown in p1973 and may not be directly
transferred into p0407 or p0408. An incorrect pole pair number (r0313, p0314) or pole pair width (p0315) results in
an incorrect value in p1973.
Note:
A negative signal indicates an incorrect polarity of the encoder signal.
Description:
Displays the number of pulses determined during the vibration test.
Note:
A negative signal indicates an incorrect polarity of the encoder signal.
Description:
Displays the status to check and monitor the states of speed controller optimization.
r1972[0...1]
Speed_ctrl_opt vibration test number of periods determined / n_opt period qty
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- -
-
r1973[0...1]
Encoder, pulse number identified / Pulse No. ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-
r1973
Rotating measurement, encoder test pulse number determined / n_opt pulse No.
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- -
-
r1979.0...11
BO: Speed_ctrl_opt status / n_opt status
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-