List of parameters
Parameters
1-505
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[6] = Torque characteristic identified measuring point 6
[7] = Torque characteristic identified measuring point 7
[8] = Torque characteristic identified measuring point 8
[9] = Torque characteristic identified measuring point 9
[10] = Torque characteristic identified measuring point 10
Dependency:
Refer to: r1938, r1939, p1959, p1960, r1969
Note:
- the value in r1937[0] corresponds to the torque constant (p0316) and was identified with the current in r1935[10].
If the reluctance torque is identified (p1959.7 = 1), the torque constant is identified with 150% rated current (p0305),
otherwise with 100% rated current.
- if indices r1937[1...10] are not equal to zero, they show the values of the torque characteristic identified for the cur-
rent in r1935[11...20]. The torque characteristic is identified in the range between rated current (p0305) and maxi-
mum current (p0640).
Description:
Displays the identified force constant.
Index:
[0] = Forced constant identified
[1] = Force characteristic identified measuring point 1
[2] = Force characteristic identified measuring point 2
[3] = Force characteristic identified measuring point 3
[4] = Force characteristic identified measuring point 4
[5] = Force characteristic identified measuring point 5
[6] = Force characteristic identified measuring point 6
[7] = Force characteristic identified measuring point 7
[8] = Force characteristic identified measuring point 8
[9] = Force characteristic identified measuring point 9
[10] = Force characteristic identified measuring point 10
Dependency:
Refer to: r1938, r1939, p1959, p1960, r1969
Note:
- the value in r1937[0] corresponds to the force constant (p0316) and was identified with the current in r1935[10]. If
the reluctance force constant is identified (p1959.7 = 1), the force constant is identified with 150% rated current
(p0305), otherwise with 100% rated current.
Description:
Displays the identified voltage constant.
Dependency:
Refer to: r1937, r1939, p1959, p1960, r1969
Note:
This value corresponds to the voltage constant (p0317).
r1937[0...10]
Forced constant identified / kT ident
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
29_1
Unit selection:
p0100
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [N/Arms]
- [N/Arms]
- [N/Arms]
r1938
Voltage constant identified / kE ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]