SINAMICS
S List Manual (LH1
), 07/200
7
Fi
gure 2-2
3
7
8
928 – Status
w
o
rd infeed
- 8928 -
Function diagram
8
7
6
5
4
3
2
1
fp_8928_01_eng.vsd
DO: A_INF
SINAMICS S
25.10.04 V02.05.00
Active Infeed - Status word, infeed
1
2
3
4
5
6
7
8
9
10
11
0
r3405
INF ZSW
Bit No.
12
13
14
15
r3405.3
r3405.4
r3405.0
r3405.2
r3405.6
r3405.5
r3405.1
Status word, infeed
1 = Current limit reached
1 = Infeed operates in the regenerative mode
0 = Infeed operates in the motoring mode
1 = Motoring mode inhibited
1 = Regenerative mode inhibited
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
1 = Smart Mode active
1 = Phase failure detected
Reserved
Reserved
1 = Vdc controller active
Reserved
p0115[3] (2000.00 µs)