![Siemens SINAMICS S Series List Manual Download Page 1293](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271293.webp)
Vect
or control
F
u
nct
ion
D
iag
ra
m
s
2
-12
93
© Siemens AG 2
007 All Rights Reserved
SINAMICS
S List Manual (LH1
), 07/200
7
Fi
gure 2-1
7
4
6
300 – V/f chara
c
teristic and
vo
lta
ge boo
st
- 6300 -
Function diagram
8
7
6
5
4
3
2
1
fp_6300_01_eng.vsd
DO: VECTOR
SINAMICS S
23.03.07 V02.05.00
Vector control - V/f characteristic and voltage boost
Freely programmable
[1690.4]
U_boost total
r1315
I_outp max
r0067
0
1
0
0
U_boost accel
p1311
U_boost perm
p1310
Ramp-up active
p1199.0
Control type
p1300
Mot U_rated p0304
Mot I_rated
p0305
+
+
R_stator act
r0395
U_output max r0071
Flux current control (FCC)
Dependent on the load current
Linear
Parabolic
[1690.1]
Mot U_rated p0304
U_output max r0071
U_output max r0071
f_set
0/5
1/6
2
3
19
Uf characteristic U4 p1327
Uf characteristic U3 p1325
Uf characteristic U2 p1323
Uf characteristic U1 p1321
U_output max r0071
Uf charact. f1
p1320
Uf charact.
f4 p1326
Uf charact. f2
p1322
Uf charact. f3
p1324
Mot f_rated
p0310
Mot f_rated
p0310
Mot f_rated
p0310
Mot U_rated p0304
Uf U_set independent
(0)
p1330[C]
<1>
<1> For p1320 = 0, the voltage boost via p1310 is not effective.
Refer to [1020.7]
p0115[y] (Motor Modules)