Parameters
List of parameters
1-782
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the digital output DO 1 (X542.4, X542.5, X542.6) of terminal module 31 (TM31).
Digital output 1 of TM31 is a relay output.
If the signal at the binector input p4031 is low, then terminal COM 1 (X542.5) is connected to NC 1 (X542.4). This
connection also matches the mechanical quiescent setting of the relay.
If the signal at the binector input p4031 is high, then terminal COM 1 (X542.5) is connected to NO 1 (X542.6).
Note:
DO: Digital Output
NC: Normally Closed contact
NO: Normally Open contact
Description:
Sets the signal source for terminal DI/DO 1 (X520.3) of terminal module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.1 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DO 2 (X481.7) of the Terminal Board 30 (TB30).
Note:
DO: Digital Output
Description:
Sets the signal source for terminal DI/DO 2 (X520.4) of terminal module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.2 = 1).
DI/DO: Bidirectional Digital Input/Output
p4031
BI: TM31 signal source for terminal DO 1 / TM31 S_src DO 1
TM31
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1840, 9556
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4031
BI: TM15DI/DO signal source for terminal DI/DO 1 / TM15D S_srcDI/DO 1
TM15DI_DO
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9400
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4032
BI: TB30 signal source for terminal DO 2 / TB30 S_src DO 2
TB30
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9102
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4032
BI: TM15DI/DO signal source for terminal DI/DO 2 / TM15D S_srcDI/DO 2
TM15DI_DO
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9400
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0