List of parameters
Parameters
1-737
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the denominator natural frequency for filter 2.2 (PT2, general 2nd Order filter) for APC (Advanced Positioning
Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the denominator damping for filter 2.2 (PT2, general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator natural frequency for filter 2.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator damping for filter 2.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the denominator natural frequency for filter 3.1 (PT2, general 2nd Order filter) for APC (Advanced Positioning
Control).
p3726[0...n]
APC filter 2.2 denominator natural frequency / APC Filt 2.2 fn_d
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p3727[0...n]
APC filter 2.2 denominator damping / APC Filt 2.2 D_d
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.050 10.000
0.700
p3728[0...n]
APC filter 2.2 numerator natural frequency / APC Filt 2.2 fn_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p3729[0...n]
APC filter 2.2 numerator damping / APC Filt 2.2 D_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7029
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700
p3731[0...n]
APC filter 3.1 denominator natural frequency / APC Filt 3.1 fn_d
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]