List of parameters
Parameters
1-609
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the value for fixed value 15 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2221, p2222, p2223
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2222, p2223
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2223
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222
p2215[0...n]
CO: Technology controller, fixed value 15 / Tec_ctrl fix val15
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
150.00 [%]
p2220[0...n]
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
7950
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2221[0...n]
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
7950
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2222[0...n]
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
7950
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2223[0...n]
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
7950
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0