Parameters
List of parameters
1-254
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
For a 1 signal via BI: p0858, the command "unconditionally close the holding brake" is executed and internally a
zero setpoint is entered.
Description:
Sets the signal source for the feedback signal from the line contactor.
Recommend.:
When the monitoring is activated (BI: p0860 not equal to r0863.1), then to control the line contactor, signal BO:
r0863.1 of its own drive object should be used.
Dependency:
Refer to: p0861, r0863
Refer to: F07300
Notice:
The line contactor monitoring is de-activated if the control signal of the particular drive object is set as the signal
source for the feedback signal of the line contactor (BI: p0860 = r0863.1).
Note:
The state of the line contactor is monitored depending on signal BO: r0863.1.
When the monitoring is activated (BI: p0860 not equal to r0863.1), fault F07300 is then also output if the contactor
is closed before it is controlled using r0863.1.
Description:
Sets the monitoring time of the line contactor.
This time starts each time that the line contactor switches (r0863.1). If a feedback signal is not received from the
line contactor within the time, a message is output.
Dependency:
Refer to: p0860, r0863
Refer to: F07300
Note:
The monitoring function is disabled for the factory setting of p0860.
Description:
Sets the delay time for the control command of the power unit and a line contactor, if used.
Note:
This means that it is possible to realize a shifted (delayed) pre-charging or power-on using a single ON command.
When the infeed units are active, before the line contactor is closed, an offset adjustment of the current measure-
ment is carried out for a duration of 120 ms (p3491).
p0860
BI: Line cont. fdbk sig / Line contact feedb
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
2634, 8734,
8834, 8934
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
863.1
p0861
Line contactor monitoring time / LineContact t_mon
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2634, 8734,
8834, 8934
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
5000 [ms]
100 [ms]
p0862
Power unit ON delay / PU t_on
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2610, 8732,
8832, 8932
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
65000 [ms]
0 [ms]