![Siemens SINAMICS S Series List Manual Download Page 956](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427956.webp)
Parameters
List of parameters
1-956
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
The following BICO interconnections are automatically established if the CANopen control word is mapped at one
of the locations x = 0 ... 3 in the receive process data buffer.
BI: p0840.0 = r889x.0
BI: p0844.0 = r889x.1
BI: p0848.0 = r889x.2
BI: p0852.0 = r889x.3
BI: p2103.0 = r889x.7
The write access is rejected if a CANopen control word is not mapped at one of these locations.
This also causes the project download of the commissioning software to be canceled.
Description:
Access to the CANopen control word using SDO transfer.
Dependency:
Refer to: p8790
Note:
Corresponds to the CANopen object 6040 hex + 800 hex * x (x: Drive number 0 ... 7).
Description:
Access to the CANopen object target velocity using the SDO transfer.
The value is displayed in increments/second as standard.
Note:
Corresponds to the CANopen object 60FF hex + 800 hex * x (x: Drive number 0 ... 7).
The displayed value is calculated as follows:
r8796 = n_set [RPM] / 60 s * p0408 * 2^p0418 * p8798[1] / p8798[0]
Description:
Access to the CANopen object target torque using SDO transfer.
r8795
CBC control word / Control word
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
ON/OFF1
Yes
No
-
01
Do not activate coast down
Yes
No
-
02
Do not activate a Quick Stop
Yes
No
-
03
Enable operation
Yes
No
-
07
Acknowledge fault
Yes
No
-
11
Freely interconn
High
Low
-
12
Freely interconn
High
Low
-
13
Freely interconn
High
Low
-
14
Freely interconn
High
Low
-
15
Freely interconn
High
Low
-
r8796
CBC target velocity / Target velocity
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r8797
CBC target torque / Target torque
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-