Parameters
List of parameters
1-502
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the identified (differential) d-inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1933, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
Note:
The Ld characteristic consists of the value pairs from p1932 and p1933 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
Description:
Displays the identification current of the d inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1932, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
Note:
The Ld characteristic consists of the value pairs from p1932 and p1933 with the same index.
Description:
Displays the identified (differential) q-inductance.
Dependency:
Refer to: p1909, p1910, r1932, r1933
Note:
The Lq characteristic consists of the value pairs from p1934 and p1935 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
Description:
Displays the identified (differential) q-inductance.
Dependency:
Refer to: r1935, p1959, p1960
Note:
The Lq characteristic consists of the value pairs from p1934 and p1935 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
r1932[0...19]
d inductance identified / Ld ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r1933[0...19]
d inductance identification current / Ld I_ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1934[0...9]
q inductance identified / Lq ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r1934[0...9]
q inductance identified / Lq ident
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]