![Siemens SINAMICS S Series List Manual Download Page 955](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427955.webp)
List of parameters
Parameters
1-955
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Corresponds to the CANopen object 6041 hex + 800 hex * x (x: Drive number 0 ... 7).
Re bit 10:
When the ramp-function generator is activated, the interconnection from CI: p2151 = r1119 can be changed, so that
to evaluate bit 10, the setpoint can be retrieved (taken) from in front of the ramp-function generator.
Re bit 10, 12:
When braking, the two bits must indicate the same state. This is the reason that the following parameters must be
set the same:
p2161 (speed threshold value 3, for r2199.0) = p2163 (speed threshold value 4, for r2197.7)
p2150 (hysteresis speed 3, for r2199.0) = p2164 (hysteresis speed 4, for r2197.7)
Description:
Binector input for CANopen status word bit 8.
Dependency:
Refer to: r8784
Description:
Binector input for CANopen status word bit 14.
Dependency:
Refer to: r8784
Description:
Binector input for CANopen status word bit 15.
Dependency:
Refer to: r8784
Description:
Sets the automatic BICO interconnection of the CANopen control word.
Values:
0:
No interconn
1:
Interconnection
Dependency:
Refer to: r8750, r8795, r8850
p8785
BI: CBC status word bit 8 / Status word bit 8
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p8786
BI: CBC status word bit 14 / Status word bit 14
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p8787
BI: CBC status word bit 15 / Status word bit 15
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p8790
CBC control word - auto interconnection / STW interconn auto
SERVO (CAN), VEC-
TOR (CAN)
Can be changed:
C1(3), T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0