![Siemens SINAMICS S Series List Manual Download Page 676](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427676.webp)
Parameters
List of parameters
1-676
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays status word 1 for the basic positioner (EPOS).
Dependency:
Refer to: r2684
Note:
Re bit 02, 04, 05, 06, 07:
This signals designate the state after jerk limiting.
Re bit 08, 09:
These signals are generated in the "closed-loop position control" function module.
Description:
Displays status word 2 for the basic positioner (EPOS).
r2683.0...14
CO/BO: EPOS status word 1 / PosZSW1
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
3645
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Tracking mode active
Yes
No
3635
01
Velocity limiting active
Yes
No
3630
02
Setpoint available
Yes
No
3635
04
Axis moves forwards
Yes
No
3635
05
Axis moves backwards
Yes
No
3635
06
Software limit switch minus reached
Yes
No
3635
07
Software limit switch plus reached
Yes
No
3635
08
Position actual value <= cam switching posi-
tion 1
Yes
No
4025
09
Position actual value <= cam switching posi-
tion 2
Yes
No
4025
10
Direct output 1 via traversing block
Yes
No
3616
11
Direct output 2 via traversing block
Yes
No
3616
12
Fixed stop reached
Yes
No
3616,
3617
13
Fixed stop clamping torque reached
Yes
No
3616,
3617
14
Travel to fixed stop active
Yes
No
3616,
3617
r2684.0...15
CO/BO: EPOS status word 2 / PosZSW2
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
3646
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Search for reference active
Active
Not active
3612
01
Flying referencing active
Active
Not active
3614
02
Referencing active
Active
Not active
-
03
Printing mark outside outer window
Yes
No
3614
04
Axis accelerating
Yes
No
3635
05
Axis decelerating
Yes
No
3635
06
Jerk limiting active
Yes
No
-
07
Activate correction
Yes
No
3635
08
Following error in tolerance
Yes
No
-
09
Modulo correction active
Yes
No
-
10
Target position reached
Yes
No
4020
11
Reference point set
Yes
No
3612,
3614