List of parameters
Parameters
1-725
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the voltage between L2 and L3.
Dependency:
Refer to: r0025, r0072, p3660
Note:
X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
The absolute voltage value resulting from the phase voltages is displayed in r0072[1] and smoothed in r0025[1].
Description:
Displays the voltage between L2 and L3.
Dependency:
Refer to: p3660
Note:
X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
Description:
Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency:
Refer to: p3665, r3666, p3667, p3668
Description:
Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
r3662
CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
A_INF, S_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8850, 8950,
9880
P-Group:
Closed-loop control
Units group:
5_3
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r3662[0...n]
CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
p0150
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
5_3
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r3664.0...1
BO: VSM temperature evaluation, status / VSM temp status
A_INF, S_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9886
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Temperature alarm threshold exceeded
Yes
No
-
01
Temperature fault threshold exceeded
Yes
No
-
r3664[0...n]
CO: VSM temperature evaluation, status / VSM temp status
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
p0150
Func. diagram:
9886
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-