List of parameters
Parameters
1-109
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Using the parameter, each Drive Data Set (= index) is assigned the associated Encoder Data Set (EDS) for
encoder 3.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description:
Displays the properties supported by the power unit firmware.
Notice:
This information represents the characteristics/features of the power unit firmware. It does not provide informa-
tion/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware sup-
ports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note:
Re bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage protec-
tion (p1231 = 3).
Re bit 10:
The Motor Module supports the autonomous internal voltage protection. If the voltage protection function is inter-
nally activated (p1231 = 3) the Motor Module decides autonomously - using the DC link voltage - as to whether the
short-circuit is activated.
p0189[0...n]
Encoder 3 encoder data set number / Enc 3 EDS number
SERVO, VECTOR
Can be changed:
C1(4)
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
DDS, p0180
Func. diagram:
1580, 8570
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 99
99
r0192
Power unit firmware properties / PU FW property
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Converter
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Edge modulation possible
Yes
No
-
01
Free telegram can be selected
Yes
No
-
02
Smart mode possible for Active Line Module Yes
No
-
03
Safety Integrated possible for VECTOR
Yes
No
-
06
Liquid cooling
Yes
No
-
07
SERVO pulse frequency changeover, DDS-
dependent
Yes
No
-
08
Simulation operation possible
Yes
No
-
09
Internal armature short-circuit possible
Yes
No
-
10
Autonomous internal armature short-circuit
possible
Yes
No
-
11
Infeed temperature inputs X21:1, X21:2
Yes
No
-
12
Integral normalized to half the gating unit
clock cycle freq.
Yes
No
-
13
Preparation thermal drive converter current
limit
Yes
No
-