![Siemens SINAMICS S Series List Manual Download Page 1025](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271025.webp)
List of parameters
Parameters
1-1025
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Value >= 1000 means:
Additional diagnostic values of the drive.
Dependency:
Refer to: C01711
Note:
The significance of the individual values is described in message C01711.
Description:
Setting to select and de-select the user agreement.
Values:
0:
[00 hex] De-select user agreement
172:
[AC hex] Select user agreement
Dependency:
Refer to: r9727
Description:
Displays the internal state of the user agreement.
Value = 0: User agreement is not set.
Value = AC hex: User agreement is set.
Dependency:
Refer to: p9726
Description:
Displays the checksum over the checked Safety Integrated parameters of the motion monitoring functions (actual
checksum).
Index:
[0] = Checksum over SI parameters for motion monitoring
[1] = Checksum over SI parameters for actual values
Dependency:
Refer to: p9729
Refer to: F01680
Description:
Sets the checksum using the checksum-tested Safety Integrated parameters for motion monitoring functions (refer-
ence checksum).
p9726
SI motion, user agreement selection/de-selection / SI Mtn UserAgr sel
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
00AC hex
0000 hex
r9727
SI motion user agreement, inside the drive / SI Mtn UserAgr int
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9728[0...1]
SI motion actual checksum, SI parameters / SI Mtn act CRC
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p9729[0...1]
SI motion reference checksum, SI parameters / SI Mtn ref CRC
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex