List of parameters
Parameters
1-875
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the physical address for the third signal to be traced.
The data type is defined using p4732.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the physical address for the fourth signal to be traced.
The data type is defined using p4733.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the physical address for the fifth signal to be traced.
The data type is defined using p4734.
The parameter can only be written to if the number of trace channels (p4702) is eight.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the physical address for the sixth signal to be traced.
The data type is defined using p4735.
The parameter can only be written to if the number of trace channels (p4702) is eight.
p4782[0...1]
Trace physical address signal 2 / Trace PhyAddr Sig2
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4783[0...1]
Trace physical address signal 3 / Trace PhyAddr Sig3
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4784[0...1]
Trace physical address signal 4 / Trace PhyAddr Sig4
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p4785[0...1]
Trace physical address signal 5 / Trace PhyAddr Sig5
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin