![Siemens SINAMICS S Series List Manual Download Page 36](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427036.webp)
Parameters
List of parameters
1-36
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
95:
Safety Integrated
98:
Command Data Sets (CDS)
99:
Drive Data Sets (DDS)
Dependency:
Refer to: p0003
Note:
Example:
p0004 = 3: Only the parameters for the motor are displayed.
Description:
Sets the parameter number and parameter index for display for p0006 = 2, 4 for the Basic Operator Panel (BOP).
Examples for the SERVO drive object:
p0005 = 21: Speed actual value smoothed (r0021)
p0005 = 25: Drive output voltage smoothed (r0025)
p0005 = 26: Speed actual value smoothed (r0026)
p0005 = 27: Absolute current actual value, smoothed (r0027)
Index:
[0] = Parameter number
[1] = Parameter index
Dependency:
Refer to: p0006
Note:
Procedure:
1.
The parameter number to be displayed should be set in index 0. Only the monitoring parameters (only read param-
eters) can be set, that actually exist for the actual drive object.
If the set parameter number is not indexed, or if there is an index in index 1 that lies outside the valid range of the
set parameter, then index 1 is automatically set to 0.
2.
The index that belongs to the parameter set in index 0 should be set in index 1. The permissible changes in index 1
always depend on the parameter number set in index 0.
Description:
Sets the mode of the operating display for the Basic Operator Panel (BOP) in the operating states "ready" and
"operation".
Values:
4:
p0005
Dependency:
Refer to: p0005
Note:
Mode 0 ... 3 can only be selected if also r0020, r0021 are available on the drive object.
Mode 4 is available for all drive objects.
p0005[0...1]
BOP operating display selection / BOP op_disp sel
A_INF, B_INF,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 65535
[0]
2
[1] 0
p0006
BOP operating display mode / BOP op_ disp mode
CU_S, DMC20,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
4 4