List of parameters
Parameters
1-857
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p4400
Description:
Setting to invert the position actual value for Terminal Module 41 (TM41).
0 -> Position actual value (CI: p4420) is evaluated as normal.
1 -> Position actual value (CI: p4420) is processed inverted.
Dependency:
Refer to: p4420
Description:
Sets pulse number to output the zero mark for the incremental encoder simulation/emulation.
Example:
p0408 = 2048 (encoder pulses)
p4426 = 512 (pulses for the zero mark)
--> Position direction: The zero mark is output after 512 pulses.
--> Negative direction: The zero mark is output after 1536 pulses.
Dependency:
Refer to: p0408
Note:
The pulses for the zero mark (p4426) must be less than the encoder pulse number (p0408).
For p4400 = 1, this parameter has not effect.
Description:
Sets the sensor type of the first temperature sensor for the motor temperature monitoring.
The parameter can only be changed for SME120, SME125, CU310 and CUA32.
Values:
0:
No sensor available
10:
PTC fault
11:
PTC alarm
12:
PTC alarm and timer stage
20:
KTY84
30:
Bimetallic NC contact fault
31:
Bimetallic NC contact alarm
32:
Bimetallic NC contact alarm and timer stage
Dependency:
Refer to: r0458, p0600, p0601
Note:
PTC thermistor: Tripping resistance = 1650 Ohm
p4422
TM41 position actual value inversion / TM41 s_act inv
TM41
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9676
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p4426
Incremental encoder emulation, pulses for zero mark / Enc_emul pulses ZM
TM41
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
9674
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 8192
0
p4600[0...n]
Motor temperature sensor 1 sensor type / MotTemp_sens typ 1
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 32
0