Parameters
List of parameters
1-734
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the number of the encoder used for for APC (Advanced Positioning Control).
Values:
2:
Encoder 2
3:
Encoder 3
Note:
Encoder 1 is the motor encoder and cannot be used for APC as APC requires a load measuring system.
An encoder used for APC is, regarding its fault messages, treated just like a motor encoder - this means that its
fault messages are assigned to the drive.
Description:
Setting to activate the filter for APC (Advanced Positioning Control).
Description:
Sets the filter type for the filter for APC (Advanced Positioning Control).
Description:
Sets the factor for the sub-sampling in the branch of filter 2.1 and 2.2 for APC (Advanced Positioning Control).
p3701
APC enc sel / APC enc sel
SERVO (APC)
Can be changed:
C1(4), U
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Data sets
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
2 3
2
p3704[0...n]
APC filter activation / APC filter act
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Activating filter 1.1
Yes
No
-
04
Activating filter 2.1
Yes
No
-
05
Activating filter 2.2
Yes
No
-
08
Activating filter 3.1
Yes
No
-
09
Activating filter 3.2
Yes
No
-
p3705[0...n]
APC filter type / APC filter type
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Filter 1.1 type
A. Filter 2nd ord.
Low pass (PT2)
-
04
Filter 2.1 type
A. Filter 2nd ord.
Low pass (PT2)
-
05
Filter 2.2 type
A. Filter 2nd ord.
Low pass (PT2)
-
08
Filter 3.1 type
A. Filter 2nd ord.
Low pass (PT2)
-
09
Filter 3.2 type
A. Filter 2nd ord.
Low pass (PT2)
-
p3706[0...n]
APC sub-sampling, filter 2.x / APC sub-samp. 2.x
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
1 64
1