Parameters
List of parameters
1-900
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the measured actual value of phase V as peak value.
The summed value of all power units is displayed in r0069[1].
Description:
Displays the measured actual value of phase W as peak value.
The summed value of all power units is displayed in r0069[2].
Description:
Displays the measured offset of phase U as peak value.
The summed value of all power units is displayed in r0069[3].
Description:
Displays the measured offset of phase V as peak value.
The summed value of all power units is displayed in r0069[4].
Description:
Displays the measured offset of phase W as peak value.
The summed value of all power units is displayed in r0069[5].
r7224[0...n]
CO: Par_circuit phase current actual value phase V / I_phase V act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7225[0...n]
CO: Par_circuit phase current actual value phase W / I_phase W act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7226[0...n]
CO: Par_circuit phase current actual value phase U offset / I_phase U offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7227[0...n]
CO: Par_circuit phase current actual value phase V offset / I_phase V offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7228[0...n]
CO: Par_circuit phase current actual value phase W offset / I_phase W offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]