Parameters
List of parameters
1-930
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the ACX file saved in the appropriate directory of the CompactFlash card.
Dependency:
Refer to: p1500
Note:
For a value = 9999999, the following applies: The read operation is still running.
Description:
Indicates which macro is presently being run in the drive object.
Dependency:
Refer to: p0015, p0700, p1000, p1500, r8570, r8571, r8572, r8573
Description:
Displays all of the devices connected to the CAN bus after run-up.
r8600
= 00000000 hex: No drive recognized.
= FFFF0192 hex: Several drives - drive 1 is an Active Line Module, servo drive or vector drive
= FFFF0191 hex: Several drives - 1st drive us a Terminal Module
= 00010192 hex: 1 Vector drive
= 00020192 hex: 1 Servo drive
= 01000192 hex: 1 Active Line Module
= 00080191 hex: 1 Terminal Module
Note:
Corresponds to the CANopen object 1000 hex.
For each detected drive, the device type is displayed in object 67FF hex + 800 hex * x (x: Drive number 0 ... 7).
Description:
Displays the error register for CANopen.
Bit 0: Generic error
0 signal: No error present
r8573[0...29]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r8585
Actual macro actual / Actual macro
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TM15DI_DO, TM31,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r8600
CBC device type / Device type
CU_S (CAN)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r8601
CBC error register / Error register
CU_S (CAN)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-