List of parameters
Parameters
1-309
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
Description:
Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
Description:
Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
Description:
Sets the lowest possible speed/velocity. This value is not fallen below in operation.
Note:
The parameter value applies for both motor directions of rotation.
In exception cases, the motor can operate below this value (e.g. when reversing).
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Extended
setp), VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3030
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
SERVO (Extended
setp, Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3030
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
r1078
CO: Total setpoint effective / Total setpoint eff
SERVO (Extended
setp), VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3030
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r1078
CO: Total setpoint effective / Total setpoint eff
SERVO (Extended
setp, Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3030
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
p1080[0...n]
Minimum speed / Minimum speed
SERVO (Extended
setp), VECTOR
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [RPM]
19500.000 [RPM]
0.000 [RPM]