List of parameters
Parameters
1-399
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
Description:
Displays the speed setpoint after setpoint limiting for the P component of the velocity controller.
For V/f operation, the value that is displayed is of no relevance.
Dependency:
Refer to: r1439
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
Description:
Displays the speed setpoint for the I component of the speed controller (output of the reference model after the set-
point limiting).
Dependency:
Refer to: r1438
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
Description:
Displays the velocity setpoint for the I component of the velocity controller (output of the reference model after the
setpoint limiting).
Dependency:
Refer to: r1438
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
Description:
Sets the smoothing time constant (PT1) for the speed actual value.
Dependency:
Refer to: r0063
r1438
CO: Velocity controller, velocity setpoint / v_ctrl v_set
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1550, 1590,
5030, 5040, 5042, 5210, 5300,
5620
P-Group:
Closed-loop control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
r1439
Speed setpoint, I component / n_set I_comp
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5030, 5040,
6031
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r1439
Velocity setpoint, I component / v_set I_comp
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5030, 5040,
6031
P-Group:
Closed-loop control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
p1441[0...n]
Actual speed smoothing time / n_ist T_smooth
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
4710, 4715
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
50.00 [ms]
0.00 [ms]