List of parameters
Parameters
1-625
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, p2514
Description:
Sets the signal source for the position offset.
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, r2667
Note:
When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: CI: p2516[0] = r2667
Description:
Sets the input terminal for direct measuring probe 1.
The direct measuring probe can neither be parameterized as non-cyclic (value 1 ... 6) nor as cyclic (value 11 ... 16)
measuring probe.
After it has been activated via BI: p2509 = 0/1 signal, the non-cyclic measuring probe measures once and can be
used with EPOS.
After it has been activated via the p2509 = 1 signal, the cyclic measuring probe measures cyclically and cannot be
used with EPOS.
In order to process signals faster, the direct measuring probe bypasses the handshake technique via the encoder
control and status word.
Values:
0:
No meas probe
1:
DI/DO 9 (X122.8/X121.8)
2:
DI/DO 10 (X122.10/X121.10)
3:
DI/DO 11 (X122.11/X121.11)
4:
DI/DO 13 (X132.8)
5:
DI/DO 14 (X132.10)
6:
DI/DO 15 (X132.11)
11:
DI/DO 9 cyclic
12:
DI/DO 10 cyclic
13:
DI/DO 11 cyclic
14:
DI/DO 13 cyclic
15:
DI/DO 14 cyclic
16:
DI/DO 15 cyclic
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0490, p0728, p2509, p2510, p2511
p2516[0...3]
CI: LR position offset / Position offset
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2517[0...2]
LR direct measuring probe 1 / Direct MT 1
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 16
0