Parameters
List of parameters
1-194
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the raw value of the absolute encoder actual value before the measuring gearbox.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description:
Displays the encoder control word Gn_STW according to PROFIdrive for diagnostics.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Notice:
Information on Gn_STW/Gn_ZSW can, e.g. be found in the following literature:
SINAMICS S120 Function Manual
Note:
The signal source for the encoder control word is set with p0480.
Description:
Sets the input terminal to connect probe 1.
Values:
0:
No meas probe
1:
DI/DO 9 (X122.8/X121.8)
2:
DI/DO 10 (X122.10/X121.10)
3:
DI/DO 11 (X122.11/X121.11)
4:
DI/DO 13 (X132.8)
r0486[0...2]
CO: Measuring gearbox, encoder raw value absolute / Enc raw val abs
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r0487[0...2]
Diagnostic encoder control word Gn_STW / Enc Gn_STW
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1580, 4704,
4720, 4740
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Request function 1
Yes
No
-
01
Request function 2
Yes
No
-
02
Request function 3
Yes
No
-
03
Request function 4
Yes
No
-
04
Request command bit 0
Yes
No
-
05
Request command bit 1
Yes
No
-
06
Request command bit 2
Yes
No
-
07
Mode flying measurement / search for refer-
ence
Flying measurement
Reference marks
-
13
Request absolute value cyclic
Yes
No
-
14
Request parking encoder
Yes
No
-
15
Request acknowledge encoder fault
Yes
No
-
p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
4740
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 6
0