Description:
Sets the reference quantity for forces.
All forces specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Note:
For the automatic calculation (p0340 = 1, p3900 > 0) an appropriate pre-assignment is only made if the parameter
is at the factory setting.
If a BICO interconnection is established between different physical quantities, then the particular reference quanti-
ties are used as internal conversion factor.
Example:
The actual value of the total force (r0079[0]) is connected to a test socket (e.g. p0771[0]). The actual force is cycli-
cally converted into a percentage of the reference force (p2003) and output according to the parameterized scaling.
Description:
Displays the reference quantity for power ratings.
All power ratings specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Dependency:
This value is calculated as follows:
Infeed: Calculated from voltage times current.
Closed-loop control: Calculated from torque times speed.
Refer to: p2000, p2001, p2002, p2003
Note:
If a BICO interconnection is established between different physical quantities, then the particular reference quanti-
ties are used as internal conversion factor.
The reference power is calculated as follows:
- 2 * Pi * reference speed / 60 * reference torque (motor)
- reference voltage * reference current * root(3) (infeed)
Description:
Sets the reference quantity for angle.
All angles specified as relative value are referred to this reference quantity.
The reference quantity in this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Note:
For the automatic calculation (p0340 = 1, p3900 > 0) an appropriate pre-assignment is only made if the parameter
is not inhibited from being overwritten using p0573 = 1. If a BICO interconnection is established between different
physical quantities, then the particular reference quantities are used as internal conversion factor.
p2003
Reference force / Reference force
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
8_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.01 [N]
20000000.00 [N]
100.00 [N]
r2004
Reference power / Reference power
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
14_10
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [kW]
- [kW]
- [kW]
p2005
Reference angle / Reference angle
SERVO, TM41, VEC-
TOR
Can be changed:
T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
90.00 [°]
180.00 [°]
90.00 [°]