![Siemens SINAMICS S Series List Manual Download Page 728](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427728.webp)
Parameters
List of parameters
1-728
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the hysteresis for the alarm threshold of the VSM to monitor the line filter temperature.
Dependency:
Refer to: p3667
Description:
Sets the hysteresis for the alarm threshold of the VSM to monitor the line filter temperature.
Dependency:
Refer to: p3667
Description:
Sets CT gain of the CT connected at the 10 V input of the Voltage Sensing Module (VSM).
The parameter specifies the current magnitude in [A] referred to the input voltage at the VSM in [V].
Example:
CT with 1 V per 200 A.
--> p3670 = 200
Dependency:
Refer to: r3671, r3672
Note:
The CT for phase 1 is connected at terminals X520.1 and X520.2 of the VSM.
The CT for phase 2 is connected at terminals X520.3 and X520.4 of the VSM.
Description:
Sets CT gain of the CT connected at the 10 V input of the Voltage Sensing Module (VSM).
The parameter specifies the current magnitude in [A] referred to the input voltage at the VSM in [V].
Example:
CT with 1 V per 200 A.
--> p3670 = 200
Dependency:
Refer to: r3671, r3672
p3669
VSM line filter overtemperature hysteresis / VSM filt_T hyst
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9886
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.0 [K]
50.0 [K]
3.0 [K]
p3669[0...n]
VSM line filter overtemperature hysteresis / VSM filt_T hyst
VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
p0150
Func. diagram:
9886
P-Group:
-
Units group:
21_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.00 [K]
50.00 [K]
3.00 [K]
p3670
VSM 10 V input CT gain / VSM CT_gain
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9880
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [A]
1000.000 [A]
1.000 [A]
p3670[0...n]
VSM 10 V input CT gain / VSM CT_gain
VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
p0150
Func. diagram:
9880
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [A]
1000.000 [A]
1.000 [A]