Parameters
List of parameters
1-218
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency:
Refer to: p0646, p0647, p0648
Description:
Sets the constant kT1 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency:
Refer to: p0646, p0647, p0648
Description:
Sets the constant kT3 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency:
Refer to: p0645, p0647, p0648
Description:
Sets the constant kT5 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency:
Refer to: p0645, p0646, p0648
p0645[0...n]
Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl)
Can be changed:
C2(1, 3), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
0.00 [Nm/A]
200.00 [Nm/A]
0.00 [Nm/A]
p0645[0...n]
Motor-torque characteristic kT1 / Mot kT1
SERVO (Exp M_ctrl,
Lin)
Can be changed:
C2(1, 3), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
0.00 [N/Arms]
200.00 [N/Arms]
0.00 [N/Arms]
p0646[0...n]
Motor-torque characteristic kT3 / Mot kT3
SERVO (Exp M_ctrl)
Can be changed:
C2(1, 3), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- -
-
p0647[0...n]
Motor-torque characteristic kT5 / Mot kT5
SERVO (Exp M_ctrl)
Can be changed:
C2(1, 3), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1