List of parameters
Parameters
1-441
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the internally converted factor to interconnect to the scaling of the torque/force limits.
Dependency:
Refer to: p1528, p1529, p1542, p1544, p1545
Description:
Sets the evaluation for the torque/force reduction when traversing to a fixed stop.
Dependency:
Refer to: p1528, p1529, p1542, r1543, p1545
Note:
4000 hex (16384 dec) in the MOMRED control word corresponds to a reduction by the percentage specified in this
parameter.
Description:
Sets the evaluation for the torque/force reduction when traversing to a fixed stop.
Dependency:
Refer to: p1528, p1529, p1542, r1543, p1545
Note:
4000 hex (16384 dec) in the MOMRED control word corresponds to a reduction by the percentage specified in this
parameter.
Description:
Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Dependency:
Refer to: p1542, r1543, p1544
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
When traveling to fixed stop, the fault F07900 "motor blocked" is suppressed.
When the function module "position positioner" (r0108.4 = 1) is activated, this binector input is interconnected as
follows as standard:
BI: p1545 = r2683.14
r1543
CO: Travel to fixed stop force scaling / TfS F scal
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5610
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p1544
Travel to fixed stop evaluation, torque reduction / TfS M_red eval
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5610
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [%]
65535 [%]
100 [%]
p1544
Travel to fixed stop evaluation force reduction / TfS F_red eval
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5610
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [%]
65535 [%]
100 [%]
p1545[0...n]
BI: Activates travel to a fixed stop / TfS activation
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 3617
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0