List of parameters
Parameters
1-665
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice:
If, when calculating the traversing profile, it is identified that the target position with the programmed deceleration
override cannot be reached without reversing the direction, then when accepting the dynamic values, the larger
deceleration override is accepted and becomes effective.
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the deceleration override is either transferred continuously or edge-triggered.
The signal value 4000 hex (16384 dec) corresponds to 100 %.
Description:
Sets the signal source for the velocity override.
This velocity override is effective in the following operating modes "direct setpoint input/MDI", "traversing blocks",
"jogging" and "search for reference" (when approaching the reference cam).
Dependency:
Refer to: p2571, p2585, p2586, p2605, p2618, p2643, r2681
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The effective override (r2681) can differ from the specified override due to limits (e.g. maximum velocity).
Description:
Sets the signal source for selecting the operating mode "direct setpoint input/MDI".
Dependency:
Refer to: p2640, p2641, p2642, p2643, p2644, p2645, p2646, p2648, p2649, p2650, p2651, p2652, p2653
Note:
In this mode, using BI: p2653 it is possible to make a flying changeover between setting-up and positioning.
In this mode, even if the axis is not referenced (r2684.11 = 0) relative positioning is possible.
Description:
Sets the signal source for the positioning type in the mode "direct setpoint input/MDI".
BI: p2648 = 1 signal
Absolute positioning is selected.
BI: p2648 = 0 signal
Relative positioning is selected.
Dependency:
Refer to: p2649, p2650, p2654
Refer to: A07461, F07488
Notice:
Absolute positioning:
To traverse, the reference point must be set (r2684.11 = 1).
Relative positioning:
To traverse, it is not necessary that the reference point is set.
Note:
Depending on p2649, the positioning type is either transferred continuously or edge-triggered.
p2646
CI: EPOS velocity override / v_over
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p2647
BI: EPOS direct setpoint input/MDI selection / MDI selection
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3640
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2648
BI: EPOS direct setpoint input/MDI positioning type / MDI pos_type
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3620
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0