Parameters
List of parameters
1-464
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Note:
For an extended general 2nd order filter, by inserting the same natural frequency in both the numerator and in the
denominator, i.e. bandstop frequency, a bandstop filter is implemented. If the numerator damping of zero is
selected, the bandstop frequency is completely suppressed. The denominator damping can be determined from the
equation for the 3 dB bandwidth: f_3dB bandwidth = 2 * D_denominator * f_bandstop frequency
Description:
Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the denominator damping for current setpoint filter 2.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
Description:
Sets the numerator damping for current setpoint filter 2.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
p1663[0...n]
Current setpoint filter 2 denominator natural frequency / I_set_filt 2 fn_n
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5710, 6710
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
1999.0 [Hz]
p1664[0...n]
Current setpoint filter 2 denominator damping / I_set_filt 2 D_n
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5710, 6710
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.001 10.000
0.700
p1665[0...n]
Current setpoint filter 2 numerator natural frequency / I_set_filt 2 fn_z
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5710, 6710
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
1999.0 [Hz]
p1666[0...n]
Current setpoint filter 2 numerator damping / I_set_filt 2 D_z
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5710, 6710
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700