![Siemens SINAMICS S Series List Manual Download Page 480](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427480.webp)
Parameters
List of parameters
1-480
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the configuration for the adaptation circuit of the motor model.
Induction motor (ASM): Rs, Rr (only for operation with encoder), Lh and offset compensation.
Permanent magnet synchronous motor (PEM): kT
Caution:
For the PEM kT adaptation (p1780.3) as well as the compensation of the voltage emulation error (p1780.8) and for
the kT(iq) characteristic (p1780.9), the function module "Extended torque control" (r0108.1) should be activated.
Note:
ASM: Induction motor
PEM: Permanent magnet synchronous motor
Description:
Sets the configuration for the adaptation circuit of the motor model.
Induction motor (ASM): Rs, Rr (only for operation with encoder), Lh and offset compensation.
Permanent magnet synchronous motor (PEM): kT
Caution:
For the PEM kT adaptation (p1780.3) as well as the compensation of the voltage emulation error (p1780.8) and for
the kT(iq) characteristic (p1780.9), the function module "Extended torque control" (r0108.1) should be activated.
Note:
ASM: Induction motor
PEM: Permanent magnet synchronous motor
The kT adaptation and the kT characteristic can be simultaneously selected.
Re kT adaptation (p1780.3 = 1):
- the kT adaptation is only active at a speed greater than the changeover speed with encoder (p1752).
- beforehand, an identification of the voltage emulation error must be started (p1909.14 = 1).
If the electrical configuration/structure (e.g. motor module, cabling) or the pulse frequency (p1800) changes,then a
new identification run must be made.
p1780[0...n]
Motor model adaptation configuration / MotMod adapt conf
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-
-
0010 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
03
Select motor model PEM kT adaptation
Yes
No
-
05
Select ASM Rr adaptation (only with
encoder)
Yes
No
-
07
Select T(valve) with Rs adaptation
Yes
No
-
08
Compensation voltage emulation error in
the drive converter
Yes
No
-
09
kT(iq) characteristic active
Yes
No
-
p1780[0...n]
Motor/converter model adaptation configuration / MotMod adapt conf
SERVO (Exp M_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-
-
0000 0001 0010 1000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
03
Select motor model PEM kT adaptation
Yes
No
-
05
Select ASM Rr adaptation (only with
encoder)
Yes
No
-
07
Select T(valve) with Rs adaptation
Yes
No
-
08
Compensation voltage emulation error in
the drive converter
Yes
No
-
09
kT(iq) characteristic active
Yes
No
-